Features
- LONG-DISTANCE WIND BLAST
The optimized air duct design synergizes with the turbo fan speed to deliver stronger air flow at air speed >0.3m/s, with a distance reaching up to 12 meters - 3D AIRFLOW
The direction air-outlet moves automatically both horizontally & vertically, directing airflow to fill in every corner of the room. - GOLDEN FIN
The Golden Fin technology is more resistant to oxidation & corrosion than ordinary blue fins. It can effectively prevent bacteria from breeding
& spreading & withstand corrosive elements. - SMART DIAGNOSIS
Digicom Air conditioner automatically tests 97 functions via its mobile app. If a problem is detected, the air conditioner will display the error “EC”. By simply swiping your finger you can give your air conditioner a checkup, allowing you to conduct maintenance promptly. It’s just as having a private doctor for your air conditioner. - DUAL DC ROTARY COMPRESSOR
Improving the design of inverter compressors further, DIGICOM Inverter ACs with two rotary compressors instead of one. Dual inverter ACs are a step ahead of ordinary inverter ACs. - HEATING & COOLING
DIGICOM air conditioners are for all seasons having both heating and cooling functions making them suitable for warmth in winters and cool in summers. - ELECTRICITY SAVING
DIGICOM inverter AC efficiently controls motor speed by maintaining set temperature & cooling whether n room temperature rises above the set temperature & heating when the room temperature falls below the set temperature. - WIFI CONTROL
Another way you can control DIGICOM AC is through Wi-Fi. It does not need a separate third-party controller as the WiFi capabilities are built-in. Control your AC with the on-the-go
- INVERTER TECHNOLOGY :
DIGICOM’s inverter technology is a true innovation in the field of climate control. The principle is simple: inverters adjust the power used to suit the actual requirement – no more, no less! This technology provides you with two concrete benefits: - COMFORT:
The inverter repays its investment many times over by improving comfort. An air conditioning system with an inverter continuously adjusts its cooling and heating output to suit the temperature in the room thus improving comfort levels.
The inverter reduces system start-up time enabling the required room temperature to be reached more quickly. As soon as the correct temperature is
reached, the inverter ensures that it is constantly maintained. - ENERGY EFFICIENT :
Because the inverter technology monitors and adjusts ambient temperature
whenever needed, energy consumption drops by 40% compared to a traditional on/off system! (non-inverter)
MODEL NUMBER | DG-1210IV/MD | DG-1810IV/MD | DG_2410IV/MD | ||
TON | 1 TON | 1.5 TON | 2 TON | ||
POWER SUPPLY | PH-V-HZ | 220-240V-50Hz, 1ph | 220-240V,50Hz, 1ph | 220-240,50Hz, 1ph | |
COOLING | CAPACITY | BTU/H | 12000 | 18000 | 24000 |
INPUT | W | 1100 | 1650 | 2190 | |
RATED CURRENT | A | 4.8A | 7.5 | 9.5 | |
EER | W/W | 3.21 | 3.2 | 3.21 | |
HEATING | CAPACITY | BTU/H | 12000 | 18000 | 24000 |
INPUT | W | 1050 | 1460 | 2060 | |
RATED CURRENT | A | 4.8A | 6.5 | 9,0 | |
COP | W/W | 3.33 | 3.61 | 3.41 | |
MAX.INPUT CONSUMPTION | W | 2050 | 2300 | 2500 | |
MAX.CURRENT | A | 9.5 | 12 | 11.5 | |
STARTING CURRENT | A | / | / | / | |
COMPRESSOR | MODEL | ASN98D22UFZ | ASN140D21UFZ | ATF235D22UMT | |
TYPE | ROTARY | ROTARY | ROTARY | ||
BRAND | / | / | / | ||
CAPACITY | W | / | / | / | |
INPUT | W | 748 | 1085 | 1970 | |
RATED CURRENT(RLA) | A | 5.35 | 7.58A | 6.95 | |
LOCKED ROTOR AMP(LRA) | A | / | / | / | |
THERMAL PROTECTOR | / | / | / | ||
THERMAL PROTECTOR POSITION | / | / | / | ||
CAPACITOR | MF | / | / | / | |
REFRIGERANT OIL/OIL CHARGE | ML | Ester Oil VG74 370ml | Ester Oil VG74/440 | ESTER OIL VG74/670 | |
INDOOR FAN MOTOR | MODEL | YKFG-20-4-5 | ZKFP-30-8-3 | YKFG-45-4-22 | |
INPUT | W | 45 | / | 72 | |
CAPACITOR | UF | 1.5 | / | 3 | |
SPEED(HI/ML/LO) | R/MIN | / | 1200/950/750 | ||
INDOOR COIL | A NUMBER OF ROWA | 2 | 2 | 2 | |
B.TUBE PITCH (A)X ROW PITCH (B) | MM | 21 x 13.37 | 21 x 13.37 | 21 x 13.37 | |
C.FIN SPACING | MM | 1.3 | 1.2 | 1.3 | |
D.FIN TYPE (CODE) | Hydrophilic aluminum | Hydrophilic aluminum | Hydrophilic aluminum | ||
E.TUBE OUTSIDE DIA.AND TYPE | MM | Φ7,innergroove tube | Φ7,innergroove tube | Φ7,innergroove tube | |
F.COIL LENGTH x HEIGHT x WIDTH | MM | 605 x 294 x 26.74 | 750x336x26.74 | 820x336x26.74 | |
G.NUMBER OF CIRCUITS | 2 | 4 | 4 | ||
INDOOR AIR FLOW (HI/MI/LO) | M3/H | 801/608/502 | |||
INDOOR NOISE LEVEL (HI/MI/LO) | DB(A) | 41/33/25 | 47.2/-/32 | 48/42/33 | |
INDOOR UNIT | DIMENSION(W x D x H) | MM | 802 x 189 x 297 | 965 x 215 x 319 | 1080 x 226 x 335 |
PACKING (W x D x H) | MM | 875 x 285 x 375 | 1045 X 305 X 405 | 1155 x 415 x 315 | |
NET/GROSS WEIGHT | KG | 8.8/11.2 | 11.6/14.8 | 12/15 | |
OUTDOOR FAN MOTOR | MODEL | YKT-32-6-203L | YKT-32-6-203L | YKT-57-6-200L | |
INPUT | W | 72.5 | 72.5/67 | 106/85 | |
CAPACITOR | UF | 2.5 | 2.5UF/450V | 3 | |
SPEED | R/MIN | 860 / — / — | 850/770 | 900/–/780 | |
OUTDOOR COIL | A.NUMBER OF ROWS | 1 | 2 | 2 | |
B.TUBE PITCH(A) x ROW PITCH(B) | MM | 21 x 13.37 | 21 x 13.37 | 21 x 12.37 | |
C.FIN SPACING | MM | 1.4 | 1.2 | 1.4 | |
D.FIN TYPE (CODE) | Hydrophilic aluminum | Hydrophilic aluminum | Hydrophilic aluminum | ||
E.TUBE OUTSDIE DIA.AND TYPE | MM | Φ7,innergroove tube | Φ7,innergroove tube | Φ7,innergroove tube | |
F.COIL LENGTH*HEIGHT*WIDTH | MM | 755 x 504 x 13.37 | 860 x 504 x 26.74 | 760 x 651 x 26.74 | |
G.NUMBER OF CIRCUITS | 2 | 4 | 6 | ||
OUTDOOR AIR FLOW | M3/H | ||||
OUTDOOR NOISE LEVEL | DB(A) | 54 | 55.3 | 58 | |
OUTDOOR UNIT | DIMENSION(W x D x H) | MM | 770 x 300 x 555 | 800 x 333 x 554 | 845 x 363 x 702 |
PACKING (W x D x H) | MM | 900 x 345 x 585 | 920 x 390 x 615 | 965 x 395 x 765 | |
NET/GROSS WEIGHT | KG | 26.6/29 | 35.5/38.3 | ||
REFRIGERANT TYPE | G | R410A/760 | R410A/1400 | R410A/1650 | |
DESIGN PRESSURE | MPA | 4.2/1.5 | 4.2/1.5 | 4.2/1.5 | |
REFRIGERANT PIPING | LIQUID SIDE/GAS SIDE | MM(IN) | Φ6.35/Φ12.7(1/4″/1/2″) | Φ6.35/Φ12.7(1/4″/1/2″) | Φ9.52/Φ15.9(3/8″/5/8″) |
MAX. REFRIGERANT PIPE LENGTH | M | 25 | 30 | 30 | |
MAX.DIFFERENCE IN LEVEL | M | 10 | 20 | 20 | |
CONNECTION WIRING | 4 x 1.5(Optional) | 4 x 2.5(optional) | 4 x 1.5(optional) | ||
PLUG TYPE | 3 x 1.5/BSR | 3 x 2.5 /- | 3 x 2.5 | ||
THERMOSTAT TYPE | Remote Control | Remote Control | Remote Control | ||
OPERATION TEMPERATURE | M | 17-30 | 17-30 | 17-30 | |
ROOM TEMPERATURE | INDOOR(COOLING/HEATING) | M | 17-32/0-30 | 17-32/0-30 | 17-32/0-30 |
OUTDOOR(COOLING/HEATING) | M | 0-50/-15-30 | 0-50/-15-30 | 0-50/-15-30 | |
APPLICATION AREA (COOLING STANDARD) | M | 16-23 | 24-35 | 28-41 |